I got this from an estate and it was missing the manuals, which are the heart of the program. A simple front panel with 2 unassigned pots and an On-Off switch. A nice open-frame test-bed for experimentation. Rear view showing the output to the scope. The silk-screening looks crooked! Back of front panel showing wiring for pots. Slide switch controls the battery supply under the chassis. I forgot to take a pic of the battery holder.

How To Hook Up Ignition Scope On A 2005 Bmw Z4

November 9, When men were men, and oscilloscopes were oscillographs. Do you remember your first oscilloscope? Maybe we have entered the era in which younger readers think of a sleek model with an LCD screen, but for the slightly older among us the image that will come to mind is likely to be a CRT-based behemoth. Mine was a 2MHz bandwidth Cossor from the s, wildly outdated by the s, but it came to me at no cost. I still have it, as a relic and curio.

The oscilloscope will reveal the complex frequencies and wave shapes of audio signals from music, speech and other sounds. If you use a “Y” adapter cable, you can hear the music and watch the oscilloscope at the same time.

For example, if you want to verify that the output from a pin of an integrated circuit is emitting a square wave, touch the oscilloscope probe to the pin and look at the display on the scope. But once you get those settings adjusted correctly, you should be able to visualize the square wave. Never connect the oscilloscope probe directly to an electrical outlet.

If you want to measure voltage from an outlet, just use your regular multimeter. The following paragraphs give a few ideas for viewing various kinds of waveforms with an oscilloscope: To view a simple DC waveform, try connecting the oscilloscope to a 1. The resulting display should be a simple straight line midway between the second and third vertical division above the centerline. If the battery is dead or weak, this line may be lower. If you want to see the 60 Hz sine wave available from an electrical wall outlet, find a plug-in power supply commonly called a wall wart that generates low-voltage AC.

Plug one end into the headphone jack of any audio device, such as a radio or an iPod.

Test Probes

Input Phase Angle and number of transformers needed. For High-Delta, type of transformer. It is used in business where you’re not running a lot of heavy motorized equipment.

A really good solution is to pick up a Magnum Signal Sleuth, which is a purely linear device that preselects signals before it gets to your receiver’s mixing stages. Check out the review on the reviews page for more on the Signal Sleuth, including links to the manufacturer.

Product Overview E-Z-Hook has been manufacturing electronic test accessories used for test and measurement purposes since Our extensive product line and custom solution services are utilized by companies in multiple industry sectors. Our focus on quality, customer service and innovation is why leading firms have depended on E-Z-Hook components for over half a century. E-Z-Hooks continued dedication to quality products is reflected in our manufacturing process which includes carefully engineered tooling, selected materials and proven product usefulness through field testing.

Our products are designed to provide trouble-free service and field durability. Test Hooks Originator of the hypo-action hook, E-Z-Hook continues to expand its test hook line to meet industry demands. We provide answers to your micro, mini and macro connection requirements with precision and quality. Select from our extensive range of micro, mini and macro test hooks including single hook, double hook and insulation piercing options. E-Z-Hook manufactures a variety of styles, including hooks for high temperature and non-magnetic environments.

Fluke 190-204 ScopeMeter® Test Tool

Test for harmonics, transients and loads at the three-phase power input Troubleshoot dc to ac converters for faulty IGBT gates or filter circuits Test PWM output for reflections and transients or voltage unbalance Safely measure from mV to kV Standard probes that cover a wide application range from mV to kV prepare you for anything from micro-electronics to heavy duty medium voltage electrical applications. Independent isolated inputs eliminate the risk of accidental ground short circuits by allowing you to make measurements in mixed circuits with separate ground references.

Their sealed cases protect them from dust, water vapor, drips, humidity and airborne pollutants, ensuring reliable accurate performance every time you need them. Built in multimeter to quickly and conveniently perform precise measurements Built-in digital multimeter 4 channel model with isolated dual input scope and dedicated digital multimeter.

Once you have properly grounded the oscilloscope and yourself, and you’ve set up the oscilloscope in standard positions, you are ready to connect a probe to your oscilloscope. A probe, if well-matched to the oscilloscope, enables you to access all of the power and performance in the oscilloscope and will ensure the integrity of the signal you are measuring.

October 29, , Station Monitorscopes such as those from Heath, Kenwood and Yaesu and none are on the market today have a provision for “transmitting directly through” the scope. That is, they have a pair of SO coax receptacles right on the rear panel of the scope, and the sampling network that drives the vertical plates in the scope CRT is located there. So, to “sample the RF” to make measurements, you don’t need to do anything except splice the scope into your transmission line with a coax jumper, and adjust a “sensitivity” control to select the amount of coupling necessary for full-screen vertical deflection.

Using any other kind of scope involves you doing the sampling yourself, and providing that to the scope. In such a case, I’d always recommend making a resistive divider, rather than a capacitive or inductive one, because a resistive divider will be “flat” across a broad frequency range and provide the same level signal to the scope assuming the same transmitter power at all operating frequencies. Reactive dividers don’t do that.

Another “plus” for using a resistive divider is that you can make its termination a 51 Ohm or 47 Ohm carbon resistor, which will eliminate the effects of any coax between the sampler and the scope input. If you use reactive sampling and it’s fairly high impedance, then the coax between the coupler and the scope will form a frequency shaping network and this isn’t good.

Connect an antenna directly to oscilloscope

CH1, CH2, auto free run Trigger polarity: Rectangular, Hanning, Hamming, Blackman Averaging: USB, kbaud PC software: Professional printed circuit board with corrosion-resistant, gold-plated pads and contacts not cheap solder finish , with silkscreen to denote component locations. Sturdy ABS plastic enclosure with custom glass-fiber front- and back-panel, silkscreen. All holes pre-drilled – no drilling required.

Mar 27,  · How To Use An Oscilloscope This is a little off topic, but may interest people involved in synth DIY or those interested in learning getting a graphical display of synth work: Oscilloscopes are surprisingly easy to use once you’ve located a few basic controls.

Power on the generator and select the desired output signal: Connect the output leads to an oscilloscope to visualize the output signal and set its parameters using the amplitude and frequency controls. Attach the output leads of the function generator to the input of the circuit you wish to test. Attach the output of your circuit to a meter or oscilloscope to visualize the resulting change in signal. A function generator, which is used for testing the response of circuits to commonplace input signals, produces various voltage patterns at different frequencies and amplitudes.

The majority of function generators enable you to pick the shape of the output from several options including square wave, in which the signal immediately goes from high to low voltage; sine wave, in which the signal curves from high to low voltage like a sinusoid; and triangle wave, in which the signal goes from high to low voltage at a fixed rate. Advanced function generators — known as arbitrary waveform generators — use direct digital synthesis techniques to generate any waveform that can be described by a table of amplitudes.

On certain function generators the frequency control combines several different controls: This enables the function generator to handle the dramatic variation in frequency scale required for signals. You use a function generator by powering it on and configuring the output signal to your intended shape.

Parts Connexion

An alternator is an electromechanical device that is able to convert externally applied mechanical energy into an electrical energy through electromagnetic induction, generated by a rotating movement of its shaft. A modern alternator may be made up of the following essential elements: A central rotating field winding assembly called the rotor.

We next set up the oscilloscope timebase to show two or three cycles of the 50 Hz input. If this is a perfect sine wave it will have the appearance shown in waveform (a) below, but there may be slight irregularities due to the presence of harmonics.

This chapter briefly describes these things. In particular, proper grounding is very important for safety reasons; not just for yourself but also for the integrated circuits ICs you are testing. Setting oscilloscope controls, calibrating the oscilloscope, connecting probes, and compensating the probes are also described, along with basic oscilloscope measurement techniques.

Proper Grounding Proper grounding is an important step when you set up to take measurements or work on a circuit: Properly grounding the oscilloscope protects you from a hazardous shock. Properly grounding yourself protects your ICs from damage. To ground the oscilloscope means to connect it to an electrically neutral reference point, such as earth ground.

Ground your oscilloscope by plugging its three-pronged power cord into an outlet grounded to earth ground. Grounding the oscilloscope is necessary for safety. If a high voltage contacts the case of an ungrounded oscilloscope—any part of the case, including knobs that appear insulated—it can give you a shock. However, with a properly grounded oscilloscope, the current travels through the grounding path to earth ground rather than through you to earth ground. Grounding is also necessary for taking accurate measurements with your oscilloscope.

The oscilloscope needs to share the same ground as any circuits you are testing. Some oscilloscopes do not require separate connection to earth ground.

Fluke 190-504/S 500 MHz ScopeMeter® Test Tool

See Ordering Information for details. Education Courseware function presents lab exercise guidance on the display Fully compatible with TekSmartLab lab management software for education Designed to make your work easier The TBS Series is designed for easy operation and quick hands-on learning. Dedicated controls provide quick access to important settings, so you can evaluate signals faster.

In this section, students will learn how to make time measurements using the oscilloscope by measuring the period of a sinusoidal voltage source. 1. If necessary, ground the oscilloscope. 2. Remove the alligator clips from the leads. Connect the leads from the oscilloscope to the Function Generator. Use leads that have the same colors as the terminals 3.

They make no mention of using old-fashioned test equipment like a VTVM, a dummy load, or even a signal generator. I will now attempt to pass along some of this acquired knowledge. The oscilloscope is of course based on the cathode-ray tube, which displays the electrical signals in graphic form. It is probably the most widely-used test instrument because it can be used to observe waveforms as well as measure voltage, time, frequency, and phase angle.

Below is a simple drawing demonstrating a basic oscilloscope cathode-ray tube. Oscilloscope CRT is a simple device in and of itself. There are opposing vertical and horizontal deflection plates inside the CRT, which is not evident in the drawing above. The drawing below should make this a little clearer. Oscilloscope CRT has opposing pairs of deflection plates.

The drawing below will demonstrate that quite nicely. If you are still following along, so far so good. We are almost done with the dry theory part.

Fluke 190-204 ScopeMeter® Test Tool

Thread starter 1 Hey guys, In lab class, we often need to feed a signal from a function generator into a circuit, then scope the signal going in, and the signal coming out lets say Im doing a PID control lab and need to do step response. The input signals we work with are usually in the 1Hz kHz range – we dont work with anything in the MHz range, at least for the moment. The typical procedure is this: The grounds and signal connections are tied together, and clipped to the input of the circuit.

Apr 05,  · Fun with oscilloscope Welcome to the CB junkies cb radio forum You are currently viewing the forum as a guest. We invite you to JOIN today .

Test for harmonics, transients and loads at the three-phase power input Troubleshoot DC to AC converters for faulty IGBT gates or filter circuits Test PWM output for reflections and transients or voltage unbalance Safely measure from mV to kV Standard probes that cover a wide application range from mV to kV prepare you for anything from micro-electronics to heavy duty medium voltage electrical applications.

Independent isolated inputs eliminate the risk of accidental ground short circuits by allowing you to make measurements in mixed circuits with separate ground references. Take on the harshest conditions with the only IP rated according to IEC scope on the market Rugged and shock-proof, all ScopeMeter portable oscilloscopes are built for harsh environments.

Their sealed cases protect them from dust, water vapor, drips, humidity and airborne pollutants, ensuring reliable and accurate performance every time you need them. Built in digital multimeter to quickly and conveniently perform precise measurements Built-in digital multimeter 2-channel models with isolated dual input scope and dedicated digital multimeter.

Conveniently switch from waveform analysis to precise multimeter measurements using the built in count digital multimeter. Measure current and temperature using a suitable shunt, probe or adapter with wide range of scaling factors. Work a full shift on a single charge New high-performance batteries take advantage of Li-Ion technology to keep you going strong for up to seven hours.

WaveRunner 610Zi

Ask Question Step 1: Spec Comparison Here are the specs of the 2 scope models. Add Tip Ask Question Step 2: Get Linux Running The first step is to get Linux going if you don’t already have it.

By giving full access to the framework of the SmartScope, a whole new dimension of possibilities is opening up. In its most basic form, this open framework allows you to hook up your creation to the extension ports of the SmartScope and control it from your PC or smartphone.

This means you can’t connect it anywhere but Earth ground green wire in North America , and even then the path between your circuit and your oscilloscope plug may be so long that there is a voltage differential and capacitance, making for a rough transition back to 0V. To get around this, isolate one of your ‘scope or circuit with an isolation transformer. This gives galvanic isolation , allowing you to use a circuit ground at a different potential than your oscilloscope ground.

Not all transformers isolate, but many common ones do. You can use 2 like step transformers from wall warts, if you want; for example: It is good practice to measure the potential between system grounds while taking other measurements.

#9: Basic 1X and 10X Oscilloscope Probe tutorial